null
New

BIOBASE AC Series Class II Type B2 Biological Safety Cabinet

No reviews yet Write a Review
Weight:
734.10 LBS
Availability: 21-30 Days ETA.

Frequently Bought Together:

Description

Models: BSC-1100IIB2-X, BSC-1300IIB2-X, BSC-1500IIB2-X and BSC-1800IIB2-X
Voltage options: 110V / 60Hz or 220V / 50–60Hz

Product Description

The BIOBASE AC Series Class II Type B2 Biological Safety Cabinet is a total-exhaust containment workstation designed for laboratory procedures requiring personnel, product and environmental protection. Its airflow system provides 0% air recirculation and 100% external exhaust, making it suitable for applications where contaminated air must be discharged through a properly engineered facility exhaust system.

Each cabinet features dual ULPA filtration, a motorized laminated-glass front window, microprocessor controls, real-time LCD monitoring, audible and visual safety alarms, stainless-steel work surfaces and an integrated UV decontamination system. The cabinet is supplied with an exhaust blower and duct connection components for site installation. Manufacturer specifications are shown on page 1 of the supplied technical sheet.

Principal Technical Specifications

Specification Manufacturer Specification
Cabinet classification Class II, Type B2
Airflow configuration 0% recirculation; 100% exhaust
Tested front opening 200 mm / 8 inches
Maximum front opening 480 mm
Inflow velocity 0.53 ± 0.025 m/s
Downflow velocity 0.33 ± 0.025 m/s
Filtration Two ULPA filters
Filter efficiency 99.9995% at 0.12 µm
Filter monitoring Filter-life and pressure indicators
Control system Microprocessor control
Display LCD status and operating-value display
Front window Motorized, two-layer laminated toughened glass, ≥6 mm
Noise level ≤65 dB
Illumination ≥1000 lux
Electrical consumption 1300 W
Electrical outlets Two waterproof sockets; 500 W combined maximum load
Work-zone material Type 304 stainless steel
Cabinet body Cold-rolled steel with antibacterial powder coating
Mobility Footmaster leveling casters

Lighting Configuration

Model UV Lamp LED Work Lighting
BSC-1100IIB2-X 30 W × 1 12 W × 2
BSC-1300IIB2-X 30 W × 1 14 W × 2
BSC-1500IIB2-X 40 W × 1 16 W × 2
BSC-1800IIB2-X 40 W × 1 16 W × 2

 

The UV system includes an operating timer, lamp-life indicator and approximately 253.7-nanometer UV output. Interlocking controls help prevent unsafe simultaneous operation of the UV lamp, blower and front window.

Safety and Monitoring Features

The microprocessor system continuously monitors inflow velocity, downflow velocity, filter condition, exhaust-filter pressure, UV operating time, cabinet humidity and system operating time. Audible and visual warnings are provided for abnormal airflow, unsafe front-window height, filter replacement, excessive filter pressure and abnormal power interruption.

Additional features include automatic airflow-speed adjustment, power-failure memory, appointment-timing controls, front-window anti-pinch logic, remote control, foot-operated window adjustment and a removable work area designed to support cleaning and maintenance.

Standard Accessories Included

  • Base stand and leveling casters
  • Exhaust blower and exhaust duct
  • Remote control
  • Foot switch
  • Two LED lamps
  • Two UV lamps
  • Two waterproof electrical sockets
  • Drain valve

Optional equipment includes water and gas taps, an electrically height-adjustable base stand and an armrest.

Ordering and Installation Notice

This Type B2 cabinet must be connected to a compatible, externally exhausted facility ventilation system. Site review should address exhaust capacity, duct routing, room-air balance, electrical service, rigging access and applicable biosafety certification requirements before shipment.

Manufacturer-document discrepancy requiring confirmation

The uploaded pricing image identifies the quoted units as “IIA2-X,” while the requested models and technical datasheet identify them as “IIB2-X.” The quote image also lists slightly different external dimensions from the technical sheet. The listing above uses the B2 technical specifications and treats the supplied prices as provisional manufacturer-quoted prices. Written manufacturer confirmation of the B2 model designation, dimensions and pricing should be obtained before accepting a paid order.

Warranty

Three-Year Limited Warranty BIOBASE AC Series Class II Type B2 Biological Safety Cabinets purchased through Truway Health are covered by a three-year limited warranty beginning on the documented delivery date, subject to the terms of the final quotation, invoice, purchase agreement, and warranty registration. Coverage For three years, Truway Health will provide warranty support for qualifying defects in materials, workmanship, and factory-installed components under normal laboratory use. Covered components may include: Microprocessor control system and LCD display Blower controls and airflow-monitoring components Motorized front-window mechanism Factory-installed electrical components Audible and visual alarm systems Cabinet frame, enclosure, and manufacturing workmanship Warranty service may consist of remote troubleshooting, repair guidance, replacement parts, component repair, or another remedy approved by Truway Health. Year-by-Year Coverage Year 1: Qualifying replacement parts and standard remote technical support. Year 2: Qualifying replacement parts and remote diagnostic support. Year 3: Qualifying replacement parts for covered components and remote technical support. Onsite labor, technician travel, freight, installation, certification, and facility modifications are not included unless expressly stated in writing. Installation and Maintenance Requirements Warranty eligibility requires the cabinet to be: Installed and commissioned by qualified personnel Connected to the correct voltage and properly grounded electrical service Connected to a properly engineered external exhaust system Operated according to the manufacturer’s instructions Maintained, inspected, and certified at recommended intervals Used only for its intended laboratory application The B2-X cabinet operates with 0% air recirculation and 100% external exhaust, so correct ducting, exhaust balance, and facility ventilation are essential. Exclusions The warranty does not cover: ULPA filters, UV lamps, LED lamps, fuses, seals, and other consumable items Routine calibration, certification, inspection, or preventive maintenance Freight, customs charges, rigging, installation, ductwork, or HVAC modifications Onsite labor, technician travel, or return shipping unless authorized Damage caused by incorrect voltage, power surges, or improper grounding Chemical corrosion, spills, contamination, or incompatible cleaning agents Broken glass, cosmetic damage, normal wear, or accidental damage Improper installation, misuse, neglect, relocation, or unauthorized modification Repairs performed by unauthorized personnel Damage caused by fire, flooding, natural disasters, or other external events Loss of samples, research materials, revenue, data, or consequential damages Freight-Damage Claims All packages must be inspected at delivery. Visible damage or shortages must be documented on the carrier’s delivery receipt before acceptance. Concealed damage should be photographed and reported promptly after unpacking. Shipping damage is handled through the applicable freight claim process and is not considered a manufacturing defect. Warranty Claim Requirements A warranty claim should include: Truway Health order or invoice number Product model and SKU Cabinet serial number Voltage configuration Delivery and installation dates Description of the fault or alarm condition Photographs or video of the issue Installation, maintenance, and certification records when requested