Description
The Truway TwinRound 700HD is the round-dome configuration of the SX-700/700HD surgical-light platform. It combines two full circular LED light heads, articulated ceiling suspension, and an integrated Sony camera system for professional surgical illumination and procedure-video workflows.
Product Overview
Purpose-built as a distinct alternative to the flower or petal-head lighting system, the TwinRound 700HD uses two conventional circular light domes with radially arranged LEDs. The round-profile design provides a recognizable operating-room form factor while maintaining independent positioning of each light head.
The ceiling-mounted suspension system includes articulated arms for the two circular domes and camera-related components. This configuration is suitable for operating rooms, surgical centers, procedure suites, and teaching environments requiring illumination combined with video viewing or documentation.
TwinRound Configuration Distinction
This listing is specifically for the twin round-dome version.
- Two complete circular LED light heads
- Continuous round-dome exterior profile
- Radially arranged LED modules
- Distinct from open-petal or flower-shaped light heads
- Separate TwinRound SKU and configuration identifier
- Sony camera-system integration
- Dual-head independent positioning
Flower-system mounting components, replacement heads, and accessories should not be assumed compatible with this TwinRound configuration unless confirmed in writing.
Key Features
- Twin circular-dome surgical-light architecture
- Ceiling-mounted dual-head configuration
- Supplier-stated total of 160 LEDs
- Integrated Sony camera system
- Independently positionable round light heads
- Multi-joint articulated suspension arms
- Central positioning handles
- Dedicated camera and display support
- Symmetrical round operating-room appearance
- Camera-assisted procedure viewing
- Suitable for clinical documentation and medical education
- Designed for professional surgical facilities
Intended Applications
- General operating rooms
- Orthopedic and trauma surgery
- Cardiothoracic procedures
- Abdominal surgery
- Gynecological and urological procedures
- Ambulatory surgical centers
- Medical teaching facilities
- Procedure-video and documentation workflows
Technical Specifications
| Specification | Details |
|---|---|
| Product Name | Truway TwinRound 700HD |
| Product Type | Dual circular-dome LED surgical light |
| Manufacturer Model | SX-700/700HD |
| Manufacturer Part Number | SX-700/700HD |
| Truway Health SKU | TWH-ORL-SX700700HD-RND-CAM |
| Configuration Code | RND-CAM |
| Light-Head Shape | Full circular/round dome |
| Number of Light Heads | 2 |
| Light Source | LED |
| LED Count | 160 LEDs, supplier stated |
| Camera System | Sony camera configuration |
| Mounting Type | Ceiling-mounted |
| Suspension | Multi-arm articulated system |
| Number of Shipping Cartons | 3 |
| Gross Shipping Weight | 130 kg / 287 lb |
| Net Product Weight | 110 kg / 243 lb |
| Shipping Volume | 0.87 m³ |
| HS Code | 9405.42 |
| Condition | New |
| Electrical Requirements | Confirm before ordering |
| Camera and Video Outputs | Confirm with final configuration |
Shipping Carton Dimensions
| Carton | Metric Dimensions | Dimensions in Inches |
| Carton 1 | 940 × 940 × 255 mm | 37.0 × 37.0 × 10.0 in |
| Carton 2 | 940 × 940 × 255 mm | 37.0 × 37.0 × 10.0 in |
| Carton 3 | 1220 × 670 × 580 mm | 48.0 × 26.4 × 22.8 in |
Standard Configuration
- Two circular LED operating-light domes
- Ceiling-mounted suspension assembly
- Independent articulated positioning arms
- Sony camera-system components
- Camera-support arm
- Display interface components specified in the quotation
- Operating-light control components
- Ceiling mounting hardware
- Installation and operating documentation
The approved quotation and purchase order determine the final included-component schedule.
Installation Requirements
Permanent professional installation is required. The purchaser must provide ceiling height, structural-support details, mounting location, room layout, electrical supply, camera-interface requirements, and applicable facility standards before ordering.
Structural reinforcement, ceiling modifications, electrical wiring, networking, recording equipment, installation labor, testing, and commissioning are excluded unless expressly included in the quotation.
Warranty
Includes a 12-month limited warranty against defects in materials and workmanship under normal professional use. Coverage excludes normal LED degradation, improper installation, unstable electrical supply, structural ceiling deficiencies, accidental damage, unauthorized modification, incompatible video equipment, and unauthorized service.
Shipping Availability
Freight shipment required. Availability and production lead time are confirmed after the round-dome configuration, voltage, camera interface, ceiling requirements, and delivery location are approved. Installation and commissioning are quoted separately.
Professional-Use Notice
For installation and use by qualified healthcare facilities and trained professionals. Confirm illumination specifications, electrical requirements, ceiling capacity, camera compatibility, regulatory status, and included components before clinical use.