Manufacturer: Medline
Product Family: Mini Vascular Access Kits
Product Type: Vascular Access / Introducer Kit
Sheath Length: 10 cm
Guidewire: 0.018 in × 45 cm
Guidewire Construction: Nitinol Core / Tungsten
Introducer Needle: 21G × 2.75 in
Available Sheath Sizes: 4 Fr and 5 Fr
Needle Options: Standard or Echogenic
Stiffness Options: Regular, Stiff, and Extra Stiff
Latex Information: Not Made with Natural Rubber Latex
UNSPSC: 42203447
Primary Packaging: 10 Kits / Case

Product Description

The Medline Mini Vascular Access Kit with Introducer Needle and Guidewire is designed to support controlled vascular access and easier catheter placement during venous, radial, and other vascular procedures.

Each kit combines a 10 cm introducer sheath, 0.018 in × 45 cm nitinol-core/tungsten guidewire, and 21G × 2.75 in introducer needle in configurations tailored to different procedural requirements.

Available variants provide a choice of 4 Fr or 5 Fr sheath size, standard or echogenic needle design, and regular, stiff, or extra-stiff guidewire/sheath characteristics.

The system incorporates a kink-resistant dilator and sheath to support smooth procedural flow and is engineered for controlled, atraumatic insertion and placement.

Key Features & Benefits

  • Mini Vascular Access System – Designed for peripheral, venous, radial, and other vascular access procedures.
  • 10 cm Sheath Length – Compact configuration suited to mini-access workflows.
  • 0.018 in × 45 cm Guidewire – Nitinol-core/tungsten construction provides controlled guidewire performance.
  • 21G × 2.75 in Introducer Needle – Facilitates initial vascular access.
  • Standard & Echogenic Needle Options – Select configurations based on procedural and visualization requirements.
  • 4 Fr and 5 Fr Options – Supports different access requirements.
  • Multiple Stiffness Configurations – Regular, stiff, and extra-stiff options available.
  • Kink-Resistant Dilator & Sheath – Designed to support smooth advancement and procedural flow.
  • Atraumatic Design – Engineered to promote smooth insertion and controlled placement.
  • Professional Vascular Use – Appropriate for hospital, catheterization, vascular-access, interventional, and procedural environments.
  • Latex Information – Not made with natural rubber latex.

Available Variants

Item # Sheath Stiffness Needle Guidewire Package
DYNJMAST03A 4 Fr Regular Standard, 21G × 2.75 in 0.018 × 45 cm Nitinol/Tungsten 10/CS
DYNJMAST04 5 Fr Regular 21G × 2.75 in 0.018 × 45 cm NT/Tungsten 10/CS
DYNJMAST09 4 Fr Extra Stiff Echogenic, 21G × 2.75 in 0.018 × 45 cm Nitinol/Tungsten 10/CS
DYNJMAST10 5 Fr Stiff Echogenic, 21G × 2.75 in 0.018 × 45 cm NT/Tungsten 10/CS
DYNJMAST12 4 Fr Regular Echogenic, 21G × 2.75 in 0.018 × 45 cm Nitinol/Tungsten 10/CS
DYNJMAST14 4 Fr Extra Stiff Standard, 21G × 2.75 in 0.018 × 45 cm Nitinol/Tungsten 10/CS
DYNJMAST16 5 Fr Regular Echogenic, 21G × 2.75 in 0.018 × 45 cm NT/Tungsten 10/CS
DYNJMAST18 5 Fr Stiff 21G × 2.75 in 0.018 × 45 cm NT/Tungsten 1 EA / 10 CS

DYNJMAST03A – 4 Fr / Regular / Standard Needle

Sheath: 4 Fr × 10 cm
Stiffness: Regular
Guidewire: Nitinol core/tungsten, 0.018 in × 45 cm
Needle: 21G × 2.75 in standard
Packaging: 10/CS

A standard-needle, regular-stiffness configuration for routine mini vascular-access procedures.

DYNJMAST04 – 5 Fr / Regular

Sheath: 5 Fr × 10 cm
Stiffness: Regular
Guidewire: NT/Tungsten, 0.018 in × 45 cm
Needle: 21G × 2.75 in
Packaging: 10/CS
GTIN: 40888277538864

Suitable where a larger 5 Fr access profile and regular stiffness are preferred.

DYNJMAST09 – 4 Fr / Extra Stiff / Echogenic Needle

Sheath: 4 Fr × 10 cm
Stiffness: Extra Stiff
Guidewire: Nitinol core/tungsten, 0.018 in × 45 cm
Needle: 21G × 2.75 in echogenic
Packaging: 10/CS

Provides enhanced stiffness with an echogenic needle for applications where ultrasound visibility and additional support are desirable.

DYNJMAST10 – 5 Fr / Stiff / Echogenic Needle

Sheath: 5 Fr × 10 cm
Stiffness: Stiff
Guidewire: NT/Tungsten, 0.018 in × 45 cm
Needle: 21G × 2.75 in echogenic
Packaging: 10/CS

Combines a 5 Fr profile with increased stiffness and an echogenic introducer needle.

DYNJMAST12 – 4 Fr / Regular / Echogenic Needle

Sheath: 4 Fr × 10 cm
Stiffness: Regular
Guidewire: Nitinol core/tungsten, 0.018 in × 45 cm
Needle: 21G × 2.75 in echogenic
Packaging: 10/CS

A regular-stiffness 4 Fr configuration with echogenic needle visibility.

DYNJMAST14 – 4 Fr / Extra Stiff / Standard Needle

Sheath: 4 Fr × 10 cm
Stiffness: Extra Stiff
Guidewire: Nitinol core/tungsten, 0.018 in × 45 cm
Needle: 21G × 2.75 in standard
Packaging: 10/CS

Extra-stiff configuration for procedures requiring greater support during insertion.

DYNJMAST16 – 5 Fr / Regular / Echogenic Needle

Sheath: 5 Fr × 10 cm
Stiffness: Regular
Guidewire: NT/Tungsten, 0.018 in × 45 cm
Needle: 21G × 2.75 in echogenic
Packaging: 10/CS

Designed for a 5 Fr access requirement with regular stiffness and enhanced needle visualization.

DYNJMAST18 – 5 Fr / Stiff

Sheath: 5 Fr × 10 cm
Stiffness: Stiff
Guidewire: NT/Tungsten, 0.018 in × 45 cm
Needle: 21G × 2.75 in
Packaging: 1 EA or 10/CS

Provides a stiff 5 Fr configuration and offers both individual-unit and case purchasing options.

Typical Applications

Suitable for professional vascular-access workflows including:

  • Peripheral vascular access
  • Radial access
  • Venous access
  • Ultrasound-guided access when an echogenic variant is selected
  • Interventional radiology
  • Cardiac catheterization environments
  • Critical-care vascular access
  • Emergency departments
  • Hospital procedure rooms
  • Vascular-access teams

Product Specifications

Specification Details
Manufacturer Medline
Product Mini Vascular Access Kit
Sheath Length 10 cm
Sheath Sizes 4 Fr / 5 Fr
Guidewire Diameter 0.018 in
Guidewire Length 45 cm
Guidewire Material Nitinol Core / Tungsten
Needle Gauge 21G
Needle Length 2.75 in
Needle Options Standard / Echogenic
Stiffness Options Regular / Stiff / Extra Stiff
Latex Information Not Made with Natural Rubber Latex
UNSPSC 42203447
Standard Case Pack 10/CS

Selection Guide

Choose the configuration according to three primary variables:

Sheath Size

  • 4 Fr: Lower-profile access option
  • 5 Fr: Larger access profile

Guidewire / System Stiffness

  • Regular: Standard procedural flexibility
  • Stiff: Increased support
  • Extra Stiff: Highest-support option among the listed variants

Needle Type

  • Standard: Conventional introducer configuration
  • Echogenic: Designed to improve visualization during ultrasound-guided access

The appropriate configuration should be selected by qualified clinical personnel based on anatomy, procedural requirements, imaging technique, access site, and institutional protocol.

Important Ordering Information

Most configurations are packaged 10 kits per case. DYNJMAST18 is additionally available as an individual unit.

Inventory may differ by item number. Some variants may be in stock, limited availability, or temporarily unavailable for online ordering.

Clinical Use Notice

These products are intended for use by trained healthcare professionals in accordance with Medline's current instructions for use, institutional vascular-access protocols, sterile technique, and applicable clinical standards.

Guidewire, needle, sheath size, stiffness, and access-site selection should be determined by qualified clinical personnel. Inspect all packaging and components before use and do not use a kit if sterile integrity has been compromised.

Warranty

The Medline Mini Vascular Access Kits are sterile, single-use medical devices. Truway Health warrants that products supplied will be new, unused, within labeled expiration dating, and supplied with intact manufacturer packaging and sterile barrier at the time of shipment. Warranty or replacement consideration may apply to products received with manufacturing defects, damaged or compromised sterile packaging, missing or defective kit components, incorrect configuration, or documented shipping damage. Because these products are sterile and single-use, opened, used, contaminated, expired, reprocessed, improperly stored, or otherwise compromised kits are not eligible for return or warranty replacement, except where required by law or where a verified manufacturing defect, recall, or manufacturer product-quality issue applies. Approved claims may be resolved through replacement, credit, or another appropriate remedy. Proof of purchase, item number, lot number, expiration date, and photographs of the affected product or packaging may be required. Any additional warranty, recall, field correction, or product-quality remedy offered by Medline remains subject to the manufacturer's current terms and applicable regulatory requirements.

Product Reviews

No reviews yet Write a Review

TRUWAY HEALTH INSTAGRAM